The concentrate is available in two packages: 500 ml and 2000 ml.
For disinfection, we use a preparation diluted with plain water.
The proportions of the preparation of the solution
Places usage |
Action bactericidal |
Action fungicidal |
Action yeasticidal |
Action virucidal |
Action combative against Clostridium difficile |
---|---|---|---|---|---|
beauty salons, aesthetic medicine, hair salons, massage, tattoo, pedicure |
2.5% -5 minutes, 20°C (dirty conditions) |
3% -15 minutes, 20°C (pure conditions) |
3% -15 minutes, 20°C (pure conditions) |
4% -30 minutes, 20°C (pure conditions) 6% - 120 minutes, 20°C (dirty conditions) |
5% - 60 minutes 20°C (pure conditions) |
Public places: hotels, spa and fitness centers, schools, kindergartens, police stations, penal and military units and catering establishments, food processing plants |
2.5% - 5 minutes, 20°C (dirty conditions) |
4.0%-15 minutes, 20°C (dirty conditions) |
3% -15 minutes, 20°C (dirty conditions) |
as above | as above |
REMEMBER! EFFECTIVE DISINFECTION REQUIRES CORRECT CONTACT TIME
Preparation of the solution
in a large BARBICIDE glass container
- Remove the product stand from the container.
- Pour one liter of water into an empty container (pure water, straight from the tap), we recommend settled water - taken from the tap at least an hour earlier.
- Do not pour more, because after adding the concentrate and inserting products with a stand, the level of the solution will rise.
- Measure the appropriate amount of BARBICIDE concentrate (according to the table above) and add it to a glass container with water.
Example : to obtain a concentration of 5%, pour 950 ml of water and add 50 ml of concentrate. - Dip the utensils and tools placed on the stand / sieve into the solution.
- Disinfected tools are left in the solution for the time indicated in the table above. The contact time depends on the selected scope of action.
Example : to inactivate bacteria, fungi, viruses and spores, leave the instruments for 60 min. in solution.
You can also prepare the solution in any larger container (e.g. bucket or ultrasonic cleaner).
DISINFECTION OF REUSABLE TOOLS OR THEIR PARTS WHICH USE DOES NOT RESULT IN VIOLATION OF THE CONTINUITY OF HUMAN TISSUES.
After each client. Suggested fluid replacement frequency: daily.
Removal of visible impurities Dipping Drying
DISINFECTION OF REUSABLE TOOLS OR THEIR PARTS WHICH USE CAUSES OR MAY CAUSE VIOLATIONS IN THE CONTINUITY OF HUMAN TISSUES.
After each client. It is necessary to change the solution after each instrument disinfection.
Dipping Sterilization
DISINFECTION OF REUSABLE INSTRUMENTS OR THEIR PARTS MADE OF MATERIALS NOT ABLE TO BE STERILIZED.
After each client. It is necessary to change the solution after each instrument disinfection.
Dipping Drying
After the disinfection process, store the tools in conditions that protect against contamination or damage.
Remember : the use of disposable gloves reduces the risk of infection with pathogenic microorganisms.